  • Evaporation portion has to be at or above condenser area to work

  • Heat pipes have incredibly long lifespans (up to 20 years) when operating between limitation ranges

  • Types of Heat Pipes:

    • Constant Conductance heat pipes (CCHP): fixed thermal conductance between evaporator and condenser, most popular for cooling electronics

    • Variable conductance heat pipes (VCHP): minimize temperature swings and include a non-condensable gas

      • probably not ideal for our application

    • Thermosiphons: gravity aided heat pipes without a wick structure (except possibly near evaporator)

    • Loop Heat Pipes: used for long distances and are quite expensive

      • not applicable for us

    • Rotating Heat Pipes: used to remove heat from motors and have a groove wick similar to rifles

    • Oscillating Heat Pipes: function very well against gravity, strong for larger/longer areas