Submission Checklists:
Sanger DNA Sequencing Submission Checklist.pdf
PCR Cleanup Submission Checklist.pdf
Section | |||||||||
---|---|---|---|---|---|---|---|---|---|
|
Sanger Sequencing
A. Individual Samples (<24 samples)
- Use a 1.5 mL microfuge tube
- Provide at least 10 uL of sample (12-15 uL preferred)
- Centrifuge your sample before dropping it off at DSF
- Write your order number and sample NUMBER legibly on the cap like this:
B. 96 Well Plate (>24 samples)
- Use a 96-well PCR (i.e. conical well) plate (DSF uses Eppendorf twin-tec 951020600)
- Provide at least 10 uL of sample (12-15 uL preferred)
- Seal your plate with adhesive foil (DSF uses VWR 60941-074)
- Centrifuge your plate before dropping it off (you can use our Sorvall Legend X1)
- Write your order number legibly on the plate and foil
- Put your samples in order vertically, starting with well A1, as shown below:
PCR Cleanup
A. Individual Samples (<24 samples)
- Use a 1.5 mL microfuge tube
- Provide at least 20 uL of unpurified PCR reaction
- Centrifuge your sample before dropping it off at DSF
- Write your order number and sample NUMBER legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
- Primer should be provided at 10 uM concentration
- Write the order number AND primer name legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
B. 96 Well Plate (>24 samples)
- Use a 96-well PCR (i.e. conical well) plate (DSF uses Eppendorf twin-tec 951020600)
- Provide at least 20 uL of unpurified PCR reaction
- Seal your plate with adhesive foil (DSF uses VWR 60941-074)
- Centrifuge your plate before dropping it off (you can use our Sorvall Legend X1)
- Write your order number legibly on the plate and foil
- Put your samples in order vertically, starting with well A1, as shown below:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
- Primer should be provided at 10 uM concentration
- Write the order number AND primer name legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
What NOT to do!
PLEASE NOTE: Our goal is quick processing of samples for a quick turnaround time. Thus, please do NOT do any of the following:- Do NOT Do not pool like samples in one tube! # of sample tubes must match # of requested sequencing reactions (1:1)
- Do NOT write your sample NAME on the lid of the microfuge tube
- Do NOT submit primer separately for Sanger sequencing orders (okay for PCR Cleanup only)
- Do NOT . 1 tube = 1 sequencing reaction!
- Do not put sample NAME on your tubes
- Do not give us your primer (unless you are requesting PCR cleanup)
- Do not use 0.5 mL microfuge tubes for samples or primersDo NOT submit non-centrifuged samples. If there is at least 4 uL at bottom, we will use as is.
- Do NOT not submit orders of >48 samples in individual tubes
- Do NOT use standard aluminum foil to cover your 96 well platesnot ask us if we will run your samples after 10:00 A.M.
Thank you for your cooperation!