Submission Checklists:
Sanger DNA Sequencing Submission Checklist.pdf
PCR Cleanup Submission Checklist.pdf
Column |
---|
Column |
---|
We reserve the right to delay or refuse any order with samples that do not meet the requirements above or below! |
width | 15 |
---|
What NOT to do!
- Do not pool like samples. 1 tube = 1 sequencing reaction!
- Do not put sample NAME on your tubes
- Do not give us your primer (unless you are requesting PCR cleanup)
- Do not use 0.5 mL microfuge tubes
- Do not submit orders of >48 samples in individual tubes
- Do not ask us if we will run your samples after 10:00 A.M.
Thank you for your cooperation!
Sanger Sequencing
A. Individual Samples (<24 samples)
- Use a 1.5 mL microfuge tube
- Provide at least 10 uL of sample (12-15 uL preferred)
- Centrifuge your sample before dropping it off at DSF
- Write your order number and sample NUMBER legibly on the cap like this:
- cap
B. 96 Well Plate (>24 samples)
- Use a 96-well PCR (i.e. conical well) plate (DSF uses Eppendorf twin-tec 951020600)
- Provide at least 10 uL of sample (12-15 uL preferred)
- Seal your plate with adhesive foil (DSF uses VWR 60941-074)
- Centrifuge your plate before dropping it off (you can use our Sorvall Legend X1)
- Write your order number legibly on the plate and foil
- Put your samples in order vertically, starting with well A1, as shown below:
PCR Cleanup
A. Individual Samples (<24 samples)
- Use a 1.5 mL microfuge tube
- Provide at least 20 uL of unpurified PCR reaction
- Centrifuge your sample before dropping it off at DSF
- Write your order number and sample NUMBER legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
- Primer should be provided at 10 uM concentration
- Write the order number AND primer name legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
- .
B. 96 Well Plate (>24 samples)
- Use a 96-well PCR (i.e. conical well) plate (DSF uses Eppendorf twin-tec 951020600)
- Provide at least 20 uL of unpurified PCR reaction
- Seal your plate with adhesive foil (DSF uses VWR 60941-074)
- Centrifuge your plate before dropping it off (you can use our Sorvall Legend X1)
- Write your order number legibly on the plate and foil
- Put your samples in order vertically, starting with well A1, as shown below:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
- Primer should be provided at 10 uM concentration
- Write the order number AND primer name legibly on the cap like this:
- Provide at least 3 uL of primer per sample in a 1.5 mL microfuge tube
What NOT to do!
- Do not pool like samples. 1 tube = 1 sequencing reaction!
- Do not put sample NAME on your tubes
- Do not give us your primer (unless you are requesting PCR cleanup)
- Do not use 0.5 mL microfuge tubes
- Do not submit orders of >48 samples in individual tubes
- Do not ask us if we will run your samples after 10:00 A.M.
Thank you for your cooperation!