Server Considerations
When considering the acquisition of servers, it is important to consider the following:
- Size of servers:
- Are these desktop/workstation form-factor?
- Are these rack-mounted servers?
- For rack-mounted severs, how many Rack Units (RU) will the servers take up in a server rack?
- Location of servers: Where are the servers going to be placed?
- Power consumption:
- Is there an adequate power source to run the servers?
- What is the power supply wattage?
- How many power supplies within the server?
- Cooling: Do you know if the heat the servers generated can be sustained in a lab?
- Server Noise: Will the server impact users in the lab or occupants in nearby rooms?
Please contact the ECE-IT group at help@ece.utexas.edu to discuss any acquisition of servers.
University Data Center (UDC)
An Enterprise-Level Data Center
Location: right off I-35 East, on Comal street (close to UT tennis center)
The University Data Center (UDC), completed in 2010, benefits campus by providing a secure, professionally managed data center to meet the growing information technology (IT) needs of researchers, colleges and schools, and administrative units at The University of Texas at Austin.
UDC Benefits and Features
- Enhanced physical and data security, redundant power and cooling systems.
- Redundant data center class high-speed networking to ensure availability of critical research and administrative systems. Support for 1GB and 10GB Ethernet. Fiber connectivity option for an additional one-time cost.
- Professional, 24/7/365 technical support and management
- Server build room enables customers to install, configure, and test systems before moving into controlled operational space.
Technical support
For any issue requiring immediate attention (less than 4 hours), such as the reboot of a server or other troubleshooting activity, call 512-471-0007. The operators are on duty 24/7 to support you and will respond within 20 minutes. Customers must provide a contact method when they contact the UDC.
Tier 1 - Typically simple tasks that can be performed in a short timeframe
Availability: 24/7/365
Services include:
- Power cycling equipment (rebooting)
- Swapping removable media (tapes, CDs, DVD, etc.)
- Visual verification of equipment state (indicators, displays, etc.)
- Console connections
- Reseating cables
- Equipment pickup and delivery
- Hard drive degaussing and destruction (for devices in the UDC)
- Inventory coordination and surplus of IT equipment
- Shipping and receiving as it relates to data center activities
- On-site assistance during customer visits – As requested/required
Tier 2 - Tasks that require more advanced involvement such as installation or handling of hardware and components.
Availability: 7 a.m. to 7 p.m. M-F
After Hours: 7 a.m. to 10 a.m. First Saturday of the month
Services include:
- Hardware failure component replacements (NICs, hard drives, power supplies, etc.)
- Installation of new hardware components (memory, hard drives) involving advance scheduling of downtime
- OOBM/DRAC/ILOM configuration
- Installation / De-installation of equipment in the raised floor and server build room
- Relocation of equipment between data halls and/or server build room
- Vendor support activities – As requested/required
- Changes to Authorized Staff Lists
Pricing
Annual Recurring Cost: Rates are based on physical size (vertical) of the server. Rates are reviewed every 3 years and maintained by the campus IT Leadership Committee (ITLC)
UT Austin Campus Rate: $270 per Rack Unit (RU). A Rack Unit is a unit of measure describing the space required to mount a server in the server rack.